Order Intraline PDO Threads M2738 for Clinics
$69.00
You save (%)
Description
Intraline® PDO Threads M2738 Mono 27G 38/50mm 5-0 is a sterile monofilament PDO thread supplied in a 20 pack for licensed clinics and healthcare professionals. Each unit pairs a 27G, 38 mm sharp-tip needle with a 50 mm absorbable 5-0 PDO thread for professional aesthetic protocols. The format is suited to clinics that need a consistent mono thread specification for treatment-room setup, documentation, and routine inventory planning.
Clinics use this mono configuration for subtle soft-tissue support and fine-line refinement within trained thread-lift workflows. The product is intended for qualified professional use, with technique, placement plane, and case selection directed by clinician training and clinic protocol.
Price, Pack Size, and Clinic Ordering
Sign in to view the current Intraline PDO Threads M2738 price and place this 20-count mono thread format into your clinic order. The pack contains two inner sets of 10 individually sterilized Tyvek pouches, helping teams plan case trays, restock treatment rooms, and document lot and expiry details at the point of use.
For purchasing accuracy, match the full specification before adding the item to your standard order set: Intraline PDO Threads M2738 Mono 27G 38/50mm 5-0 (20 pack). This exact naming helps distinguish M2738 from other Intraline mono formats with different gauges, needle lengths, or thread sizes. Account verification and professional-use ordering requirements may apply for clinic supply purchases.
Med Wholesale Supplies serves licensed clinics and healthcare professionals with brand-name medical products sourced through vetted distributors and verified supply channels. When required for applicable items, logistics may include temperature-controlled handling when required and tracked US delivery.
What the M2738 Mono Thread Is
Intraline M2738 is a smooth monofilament polydioxanone thread placed using a sharp-tip 27G needle. Polydioxanone, commonly shortened to PDO, is an absorbable suture material used as a temporary support structure after professional placement. Mono threads are smooth single filaments, so they are generally selected for skin-quality support, fine-line protocols, and subtle tissue conformity rather than the traction profile associated with barbed or cog designs.
The needle measures 38 mm, while the thread measures 50 mm and is sized 5-0. In practical clinic terms, the gauge and length combination can fit delicate facial zones when a trained practitioner wants a fine mono thread with predictable handling. For a broader explanation of absorbable threads and placement concepts, your team can reference the internal PDO threads guide.
Once implanted, the thread acts as a temporary scaffold while local tissue responds around the filament. The degree and duration of visible change vary by patient factors, technique, number of threads, area treated, and follow-up care. Clinics should avoid presenting mono threads as a substitute for surgical lifting when the treatment plan requires a different level of tissue repositioning.
Professional Applications and Treatment-Room Fit
This 27G mono thread may be incorporated into aesthetic protocols for fine static lines, early laxity support, and texture-focused treatment plans. Common professional use areas may include the neck, jawline, perioral region, periorbital area, forehead, and glabellar zone when anatomy and training support the planned technique. It can also be used as an adjunct in practices that combine thread procedures with neuromodulators, fillers, or energy-based devices.
Mono threads should be selected for the role they perform. They are smooth threads designed for supportive matrix formation and subtle refinement, not for the stronger mechanical lifting associated with cog or barbed thread formats. The distinction matters during consultation, informed consent, and treatment planning because expectations should match thread design.
- Fine-line support in thin or delicate tissue zones
- Subtle contour refinement where mono placement is appropriate
- Adjunctive use in staged rejuvenation plans
- Standardized tray setup for providers trained on 27G mono threads
- Inventory alignment for clinics using the M2738 specification repeatedly
For team education on positioning thread treatments against injectable alternatives, the article on PDO threads and Botox can help frame the difference between structural support and neuromodulator-based line reduction.
Technical Specifications
The M2738 pack is useful when staff need quick confirmation of gauge, needle length, thread length, suture size, and sterile presentation. Keeping these attributes visible in purchasing records reduces the risk of ordering a nearby but different mono format.
| Attribute | M2738 specification |
|---|---|
| Thread type | Mono PDO, single smooth filament |
| Needle gauge | 27G |
| Needle length | 38 mm |
| Needle style | Sharp tip, ultra-thin wall |
| Thread length | 50 mm |
| Suture size | 5-0 |
| Pack quantity | 20 units per box |
| Inner presentation | 2 x 10 individually sterilized Tyvek pouches |
| Outer presentation | Sealed foil outer pack |
Quick tip: Use the full M2738 specification in purchase orders, staff preference cards, and treatment templates.
Packaging, Sterile Handling, and Documentation
Each thread is supplied in an individually sterilized Tyvek pouch, with two inner sets of 10 inside a protective foil outer. This presentation supports clean handoff during procedures and helps staff open only the units needed for the planned treatment. The outer foil should remain intact until the clinic is ready to prepare the treatment room.
Labels display lot number, expiry, and product measurements for traceability. Staff should confirm the package integrity, lot, expiry, gauge, and thread length before use. Documentation should align with clinic policy, including procedure notes, informed consent, anatomical placement records, and any adverse event reporting requirements.
Store and handle sterile devices according to the manufacturer’s instructions and clinic procedures. Do not use a pouch if sterility is compromised, labeling is unclear, or the product has passed its expiry date. For broader category planning, browse medical devices used in professional aesthetic settings.
Benefits for Clinic Workflow
A fixed mono thread specification can make treatment-room preparation more repeatable. Providers and assistants can build tray lists around a known 27G, 38/50 mm, 5-0 format rather than rechecking multiple nearby configurations during setup. That consistency is helpful for multi-provider practices and clinics with standardized thread protocols.
The 20-pack size also supports routine inventory cycles. Clinics performing frequent mono thread procedures can allocate units by treatment area, staged plan, or provider schedule while maintaining clearer visibility over remaining stock. The two inner sets of 10 help organize active procedural supply and backup inventory.
- Clear specification for purchasing and staff communication
- 20-count pack for planned treatment sessions and restocking
- Individual sterile pouches for procedure-by-procedure opening
- Lot and expiry visibility for clinic documentation
- Consistent mono format for trained provider workflows
For brand-level planning and adjacent thread formats, the Intraline brand selection can help procurement teams maintain a cohesive thread portfolio.
Clinical Considerations and Safety
PDO thread placement is a professional aesthetic procedure, and outcomes depend on training, anatomy, aseptic technique, thread selection, and aftercare instructions. Adverse events may include bruising, swelling, discomfort, asymmetry, dimpling, infection, thread visibility, extrusion, migration, nerve irritation, or unsatisfactory cosmetic result. More complex complications can occur, so clinics should maintain clear escalation procedures and patient follow-up protocols.
Practitioners should screen for contraindications and risk factors before treatment. Considerations may include active infection near the treatment site, poor wound healing risk, bleeding tendency, anticoagulant use, uncontrolled medical conditions, pregnancy or breastfeeding status, prior procedures in the area, and unrealistic expectations. Individual clinical judgment and product training should guide whether mono threads, another thread format, or no thread procedure is appropriate.
Some clinicians criticize PDO thread lifts when they are oversold, used outside their best indications, or positioned as equivalent to surgery. That concern is best addressed through careful patient selection, conservative claims, anatomy-based planning, and clear consent language. The internal discussion of thread lift risks can support staff training around counseling and complication awareness.
Why it matters: A smooth mono thread is a different tool than a cog thread, surgical lift, filler, or neuromodulator.
How Long Results May Last
Mono PDO threads are absorbable, so the implanted filament does not remain permanently. The clinical effect is influenced by the temporary scaffold, tissue response, treatment density, placement pattern, and patient-specific healing. Clinics should avoid promising a fixed duration for every patient because results can differ across anatomical areas and treatment plans.
Professional counseling should explain that mono threads are often chosen for gradual support and refinement rather than immediate dramatic lift. Follow-up visits allow providers to assess symmetry, tissue response, and whether staged treatment or another modality is more appropriate. This practical framing helps align expectations with the M2738 mono thread design.
Comparable Intraline Thread Options
Clinics often keep several thread specifications in inventory because gauge, length, and thread design affect treatment planning. If M2738 is used for 27G mono protocols, nearby formats may help cover finer tissue zones, longer vectors, or different handling preferences.
For a longer 27G mono format, review Intraline PDO Mono M2750 27G 50/70mm. For a finer gauge mono option, consider Intraline Mono 29G 38/50 6-0. Practices that need a smaller 30G mono format can evaluate Intraline PDO Mono M3038 30G 38/50mm. For helical thread behavior rather than a smooth mono format, Intraline Spiral S2938 29G 38/50mm may be relevant to trained providers.
Substitution should not be automatic. Any change in gauge, thread length, suture size, or thread structure can affect technique and treatment planning. Clinical leads should approve alternates before procurement teams replace one thread model with another.
Ordering Checklist for Procurement Teams
Before placing a wholesale order, confirm the clinic needs the M2738 mono format rather than a nearby Intraline thread model. The key identifiers are 27G needle, 38 mm needle length, 50 mm thread length, 5-0 sizing, and 20 units per box. These details should match provider preference cards and treatment-room templates.
- Confirm the full product name and M2738 model reference
- Match needle gauge and length to provider protocol
- Check thread length and 5-0 size for documentation
- Plan quantities around scheduled procedures and reorder cycles
- Verify lot and expiry during receiving and before use
- Store unopened sterile packs according to clinic policy
Clinics building broader anti-aging protocols may also review Intraline applications in anti-aging treatments for product-class context and training discussion.
Authoritative Sources
For manufacturer and regulatory context, consult official and clinical references in addition to product labeling and clinic protocols.
This content is for informational purposes only and is not a substitute for professional medical advice.
Frequently Asked Questions
Who can order Intraline PDO Threads M2738?
This product is intended for licensed clinics, med spas, aesthetic practices, and healthcare professionals using trained thread-placement protocols. Account verification and professional-use ordering requirements may apply.
What is included in the M2738 20 pack?
The box contains 20 mono PDO threads. They are presented as two inner sets of 10 individually sterilized Tyvek pouches inside a sealed foil outer pack.
What are the key specifications of this thread?
M2738 uses a 27G, 38 mm sharp-tip needle with a 50 mm absorbable PDO mono thread sized 5-0. The mono design is a single smooth filament.
How should clinics document this item?
Use the full specification in purchasing records and treatment documentation: Intraline PDO Threads M2738 Mono 27G 38/50mm 5-0. Staff should also record lot and expiry according to clinic policy.
Can M2738 be substituted with another Intraline thread?
Only with clinical approval. Changes in gauge, needle length, thread length, suture size, or thread design can affect technique and treatment planning.
What safety points should providers discuss before treatment?
Providers should review patient suitability, infection risk, bleeding risk, prior procedures, expected results, and possible adverse events such as bruising, swelling, asymmetry, dimpling, infection, extrusion, or unsatisfactory cosmetic outcome.
Specifications
- Main Ingredient: Polydioxanone (Pdo)
- Manufacturer: Mecobi Co. Ltd.
- Drug Class: Medical Device
- Generic Name: Polydioxonone
- Package Contents: 20 pack
- Storage Requirements: Room Temperature (2℃~25℃)
- Main Usage:
About the Brand
Intraline
Here to help
Questions about ordering, delivery or products? You can email our team here or call now at 1-800-630-9757 and be connected with your dedicated Account Manager
Related Products
You save (%)
Juvéderm® SKINVIVE
You save (%)
You save (%)
You save (%)
Related Articles
FDA-Approved Dermal Fillers: Safety and Clinic Use
FDA-approved dermal fillers are soft tissue filler products that the U.S. Food and Drug Administration…
Glabellar Lines: Anatomy, Assessment, and Treatment Planning
Glabellar lines are the vertical frown creases between the eyebrows, often called 11 lines. In…
After Care for Botox: Clinic Instructions and Safety Checks
In clinical practice, after care for botox is the set of written and verbal instructions…
Hyaluronidase in Aesthetic Practice: Safety and Workflow
Hyaluronidase is an enzyme that breaks down hyaluronic acid, a water-binding molecule found in skin,…
Jawline Filler in Aesthetic Care: Safety and Workflow
Jawline filler is a nonsurgical dermal filler approach used to refine lower-face contour, support the…
Dermal Fillers Before and After: Assessing Results
Dermal fillers before and after review should show whether an injectable treatment produced a visible,…
Elasticity of the Skin: Assessment and Treatment Planning
Elasticity of the skin is the skin’s ability to stretch, resist deformation, and return toward…
How Long Does Mirena Last? Duration, Labeling, and Workflow
Mirena is labeled to prevent pregnancy for up to 8 years, but its labeled duration…