Order RAINBOW™ PCLA SCREW 29G38-50mm for Clinics
$119.00
You save (%)
Description
RAINBOW™ PCLA SCREW 29G38-50mm (20 pcs) is a sterile, screw-type absorbable thread supplied for professional aesthetic workflows. Licensed clinics and healthcare professionals can order this 20-piece format for treatment-room planning where a 29G delivery needle and 50 mm thread length fit the protocol. The single-spiral configuration supports controlled superficial subdermal placement by trained providers using aseptic technique.
This configuration is suited to facilities that standardise thread types by zone, session size, and operator technique. The 20-count pack helps teams stage trays, document lot use, and maintain a repeatable inventory pattern for focused thread procedures.
Product Configuration and Clinic Fit
RAINBOW™ PCLA SCREW 29G38-50mm is built around a helical monofilament thread loaded on a 29G delivery needle. The screw geometry creates a coil profile rather than a straight mono thread, which can provide different tactile feedback during insertion and withdrawal. In practice, that difference matters for clinicians who train staff on depth control, vector planning, and consistent handling.
The 29G gauge supports precise placement in small or targeted facial areas when used by appropriately trained professionals. The approximate 50 mm thread length gives coverage for localized support without requiring the longer formats often selected for broader vectors. Clinics may use medical threads PCLA screw 29G 20 pcs as a standard tray component for aesthetic contouring protocols, depending on practitioner assessment and facility guidelines.
| Attribute | Supplied detail |
|---|---|
| Product | RAINBOW™ PCLA SCREW 29G38-50mm |
| Pack size | 20 pieces |
| Thread type | Screw-type, single-spiral absorbable monofilament |
| Needle gauge | 29G |
| Thread length | 50 mm |
| Use setting | Licensed clinical and professional aesthetic facilities |
Quick tip: Match the thread length and gauge to the documented protocol before opening sterile packaging.
Price, Account Access, and Ordering
Sign in to view the current Rainbow PCLA screw 29G 50mm price, account terms, and pack availability for your clinic. Pricing may vary by purchasing profile, order volume, or contract arrangement. Because this is a professional-use product, account verification and facility purchasing controls may apply before checkout.
Clinics can order Rainbow PCLA screw 29G38-50mm online as part of a broader thread or medical-device purchase. Consolidating related formats on one purchase order can simplify receiving, documentation, and internal allocation across treatment rooms. For brand continuity, browse the RAINBOW product range when aligning similar thread configurations for staff training or formulary planning.
Med Wholesale Supplies serves licensed clinics and healthcare professionals with brand-name medical products sourced through vetted distributors and verified supply channels. For logistics planning, orders may use temperature-controlled handling when required and tracked US delivery.
How Screw Threads Work in Aesthetic Protocols
A screw thread is a monofilament formed into a spiral or helical shape. Compared with a straight mono thread, the coil profile can increase local tissue contact and provide a different insertion feel. In aesthetic practice, trained providers may incorporate screw threads into minimally invasive rejuvenation plans where localized support, tissue stimulation, and contour refinement are clinically appropriate.
The thread is designed for subdermal placement, meaning it is positioned beneath the skin rather than applied topically. Placement depth, entry point, vector choice, and the number of threads used are professional decisions. Facility protocols should define operator training requirements, skin preparation steps, sterile field management, and aftercare documentation before the product is added to routine use.
For a broader technical background on thread classes, material behaviour, and treatment planning, see What Are PDO Threads and How Do They Work?. That article can support internal education, while product selection should still follow the clinician’s treatment plan and the device instructions available to the facility.
Professional Applications and Treatment-Room Use
PCLA screw thread 29G 50mm wholesale configurations are commonly considered for focused aesthetic work in areas such as the midface, perioral region, jawline, or other small zones when the provider determines that the thread type and length are suitable. The product is not a substitute for clinical assessment. Thread selection should account for tissue thickness, treatment goals, patient history, contraindications, and the practitioner’s training.
In many clinics, screw threads are used alongside other thread categories rather than as a stand-alone inventory choice. Smooth mono threads may support broader mesh-style layouts, while cog or barbed threads may be selected for different lifting vectors. This screw format can help bridge those approaches when a provider wants a localized spiral thread in a familiar 29G delivery profile.
For category-level planning across adjacent supplies, visit Medical Devices. Clinics building a RAINBOW-focused formulary can also compare the related RAINBOW™ PCLA SCREW 29G50-80mm configuration when a longer thread length is needed for a different protocol.
Key Features for Clinical Workflows
The main value of this configuration is repeatability. A defined gauge, length, thread geometry, and pack count make it easier for teams to build trays, train staff, and document procedures consistently. The 20-piece count can suit scheduled treatment days without forcing teams to open unrelated formats or mix thread types during setup.
- Single-spiral screw design for localized tissue contact
- 29G delivery needle for precise superficial subdermal placement
- 50 mm thread length for targeted treatment zones
- Sterile, single-use format for procedural safety
- 20 pieces per pack for predictable session planning
- Absorbable monofilament structure for temporary support
- Consistent geometry for familiar insertion feedback
- Useful companion format for layered mono, spiral, or cog strategies
29G PCLA screw threads 38-50mm 20 pcs can be especially practical for clinics that assign thread types to defined indications. Standardisation may reduce tray variation, simplify staff orientation, and help supervisors review technique across multiple providers.
Composition, Sterility, and Handling
The device comprises an absorbable, suture-grade monofilament configured as a single spiral thread on a 29G delivery needle. Current product information describes the thread material as polydioxanone (PDO), a synthetic biocompatible polymer with a history of use in absorbable surgical sutures. The RAINBOW™ PCLA SCREW name should be matched to the product packaging and facility purchasing record during receiving.
Each thread is supplied sterile and intended for single use. Staff should inspect the protective packaging before use and avoid opening any unit with compromised sterility indicators or damaged packaging. Once opened, the thread should be handled according to aseptic technique and facility policy for sterile medical devices.
Store and handle the product according to the manufacturer’s packaging directions and your clinic’s inventory controls. Receiving teams should record lot information, expiry details, and internal item identifiers so the device can be traced from purchase through treatment-room use.
Benefits for Inventory Planning
For busy aesthetic practices, the practical benefit of a 20-count screw thread pack is planning control. Teams can forecast thread consumption by procedure type, provider schedule, and expected session volume. That helps prevent unnecessary format substitutions during a treatment day and supports cleaner documentation.
Standardising a screw thread such as Rainbow™ PCLA screw threads 29G 50mm 20 pack may also support training. New staff can learn one gauge and length for defined indications before expanding to longer, shorter, or differently shaped threads. Supervisors can evaluate consistency in tray setup, sterile opening, handoff, and post-procedure recordkeeping.
Why it matters: Consistent thread formats help clinics reduce avoidable variation during high-throughput procedure days.
Comparable Thread Options
Clinics often stock several thread shapes and lengths because treatment plans vary by anatomy and clinical objective. If a spiral-style thread in a comparable gauge is needed for a different workflow, consider Intraline Spiral S2938 29G 38mm/50mm. For straight monofilament planning, Mono 29G38 may be useful where a smooth thread rather than a screw profile is preferred.
Some protocols use longer monofilament formats for broader layouts. In those cases, PCLA Mono 27G60-100mm may be reviewed as a companion product rather than a direct substitute. Selection should be based on the clinician’s technique, the intended placement area, and the device characteristics shown during ordering.
For aesthetic teams that use embossing-style monofilaments in selected protocols, Gold Embossing Mono 29G38X provides another related format to evaluate. Avoid substituting thread types without clinical approval, staff familiarity, and documentation updates.
Safety and Tolerability Notes
Thread procedures require trained professional placement, aseptic technique, and careful patient selection. Typical short-term responses after insertion may include localized bruising, swelling, tenderness, erythema, or minor discomfort at entry points. Clinics should give clients clear aftercare instructions and define when post-procedure review is needed.
Providers should assess relevant contraindications and procedural risks before treatment. Important considerations may include active skin infection at the planned site, impaired wound healing, bleeding risk, anticoagulant use, allergy history, prior procedures in the area, and unrealistic treatment expectations. Depth control is essential because improper placement can increase the risk of irregularity, visibility, pain, or other complications.
Thread use should remain within the practitioner’s training and facility governance. Document the device, lot, placement area, number of threads used, and any immediate response. If unexpected pain, marked swelling, infection signs, asymmetry, or other concerning symptoms occur, follow the clinic’s escalation pathway and arrange appropriate medical evaluation.
Documentation and Receiving Checklist
Receiving staff should confirm that the product name, count, gauge, and thread length match the purchase order before the pack enters clinical stock. For this item, the key identifiers are RAINBOW™ PCLA SCREW 29G38-50mm, 20 pieces, 29G needle, and 50 mm thread length. Internal item codes can be added to your inventory system to support reordering and traceability.
- Confirm pack integrity before stocking.
- Record lot and expiry information according to facility policy.
- Store in the designated medical-device area.
- Keep sterile units sealed until the procedure setup.
- Assign the thread format to approved protocols only.
- Document use in the treatment record after placement.
When supply needs shift, review related RAINBOW and medical-device formats before changing the protocol. Substitutions should be approved by the clinical lead, reflected in purchasing records, and communicated to staff who prepare treatment trays.
Authoritative Sources
The following external references support general safety and material context for absorbable sutures and suture materials. They are not a replacement for the manufacturer’s device instructions or clinic-specific protocols.
Ready to standardise this screw thread configuration? Sign in to add RAINBOW™ PCLA SCREW 29G38-50mm (20 pcs) to your clinic purchasing workflow and align reordering with scheduled aesthetic procedures.
This content is for informational purposes only and is not a substitute for professional medical advice.
Frequently Asked Questions
Who can order RAINBOW™ PCLA SCREW 29G38-50mm?
This product is intended for licensed clinics, med spas, aesthetic practices, and healthcare professionals using professional procurement controls. Account verification and facility purchasing requirements may apply before ordering.
What is included in the 20-piece configuration?
Each pack contains 20 sterile screw-type absorbable threads. The configuration uses a 29G delivery needle and an approximate 50 mm thread length for targeted professional placement.
How should clinics handle the sterile threads before use?
Keep each sterile unit sealed until procedure setup, inspect packaging integrity before opening, and follow your facility’s aseptic technique and device traceability procedures. Record lot and expiry details according to clinic policy.
Can this screw thread be used with mono or spiral threads?
Clinicians may incorporate screw threads with other thread formats when a layered protocol is clinically appropriate. Product selection should be based on provider training, anatomy, intended placement area, and documented facility protocols.
What safety points should providers review before treatment?
Providers should assess skin condition, infection risk, bleeding risk, allergy history, prior procedures, and healing factors before placement. Clients should receive aftercare instructions and guidance on when to contact the clinic after treatment.
Specifications
- Main Ingredient: Polydioxanone (Pdo)
- Manufacturer: PCLA Medical Devices Inc.
- Drug Class: Medical Device
- Generic Name: Pcla Screw 29G38-50 mm
- Package Contents: 20 pcs
- Storage Requirements: Room Temperature (2℃~25℃)
- Main Usage:
About the Brand
Rainbow
Here to help
Questions about ordering, delivery or products? You can email our team here or call now at 1-800-630-9757 and be connected with your dedicated Account Manager
Related Products
You save (%)
Juvéderm® SKINVIVE
You save (%)
You save (%)
You save (%)
Related Articles
After Care for Botox: Clinic Instructions and Safety Checks
In clinical practice, after care for botox is the set of written and verbal instructions…
Hyaluronidase in Aesthetic Practice: Safety and Workflow
Hyaluronidase is an enzyme that breaks down hyaluronic acid, a water-binding molecule found in skin,…
Jawline Filler in Aesthetic Care: Safety and Workflow
Jawline filler is a nonsurgical dermal filler approach used to refine lower-face contour, support the…
Dermal Fillers Before and After: Assessing Results
Dermal fillers before and after review should show whether an injectable treatment produced a visible,…
Elasticity of the Skin: Assessment and Treatment Planning
Elasticity of the skin is the skin’s ability to stretch, resist deformation, and return toward…
How Long Does Mirena Last? Duration, Labeling, and Workflow
Mirena is labeled to prevent pregnancy for up to 8 years, but its labeled duration…
Is Evenity a Bisphosphonate? Drug Class and Care Context
No. If you are asking is evenity a bisphosphonate, the short answer is no. Evenity…
What Causes Double Chin? Clinical Drivers and Red Flags
The main causes double chin presentations reflect are usually submental fat, inherited facial anatomy, chin…

